When a subscriber's TCP session to a blocked website ends, the remote server may send a stray acknowledgment packet to the BIG-IP. As there is no active session for this packet, the BIG-IP views it as unsolicited traffic and blocks that IP address in hardware. This action causes all new subscriber connections to that website to be dropped until the hardware entry expires.
The entire subscriber base at an ISP/SP deployment can lose access to websites present in the IPI feed lists, even when subscribers are the initiating party. IPI is rendered unusable in subscriber-facing service provider environments
AFM is provisioned with an IP Intelligence global policy using a feed list -- The platform supports SPVA hardware offload, and force_sw_dos is not enabled -- A subscriber initiates a TCP session to an endpoint whose IP address is present in the feed list -- The session is torn down (client sends RST-ACK; BIG-IP tears down the flow and forwards the RST-ACK to the endpoint) -- The remote endpoint sends a packet back to BIG-IP after the session entry has already been removed
Disable SPVA hardware offload for IPI by setting force_sw_dos true (trades hardware blocking for software-only enforcement, with performance impact), or remove the global IPI policy. Neither is acceptable long-term for ISP deployments
- SP Endpoint Tracking: The SP Endpoint tracking feature for the IPI global policy allows tracking of blocked endpoint IPs in a per-TMM database with three states: NONE, NEG, and POS. When enabled via "tmsh modify sys db dos.ipint.sp_endpoint.enabled value true" (requires TMM restart), if a subscriber connects to a blocked endpoint, it is promoted to POS, allowing traffic through in software, while unsolicited inbound traffic is still dropped. This feature is disabled by default and requires opt-in - SPVA Programming Rate Gate: A configurable per-source rate threshold for SPVA hardware shun programming is introduced, controlled by "tmsh modify sys db dos.ipint.spva.global.program_rate value <N>". When set to N (pps), hardware shun is programmed only if the source packet rate meets or exceeds N packets per second. The default value of 0 maintains existing behavior of immediate HW programming