Management connectivity is lost after licensing BIG-IP 17.5.0 on AWS. The parameter provision.managementeth was changed to non-eth0 interface during deployment with cloud-init. When the issue occurs, the mgmt bridge loses the associated interface ethX.
Management connectivity is lost to BIG-IP instance.
1. Deploy an instance on AWS. 2. Change provision.managementeth to non-eth0 device and reboot. 3. After boot up, any operation that restart tmm (i.e. licensing BIG-IP) will cause the issue.
Reboot the device twice after licensing the device. One reboot will not resolve the issue.