- The Traffic Groups GUI on a device in a device group reports the following even if the traffic group is in sync: “The traffic group configuration on this device does not match with other devices. Sync the Configuration between devices.” - Traffic group CRC values are consistent among peer devices when dumping the sod registers into /var/log/sodlog using the command /bin/cmd_sod get info. - Restarting sod does not change the DB var failover.crcvalues from 'disagree' to 'agree'.
The GUI displays the incorrect message in contrast to the actual state of the traffic group.
The DBVAR failover.crcvalues was previously set to disagree before the sod restart.
-- Ensure that the traffic groups are in sync and the peers agree on the CRC values. -- Manually set the db var failover.crcvalues to 'agree' on the affected device. The commands would be: tmsh modify sys db failover.crcvalues value agree tmsh save sys config