The High-Speed Bridge (HSB) version 2.12.4.0 bitstream is available for VIPRION B2250 blades.
Unable to capture or provide RQM debugging data for HSB bitstreams on VIPRION B2250 blades. - 'DNS malformed' DoS vector drops valid DNS queries for qnames that begin with an underscore character, refer ID 1156753. - Client enables Window Scale in the first SYN packet with a specific factor value, however the BIG-IP system disables Window Scale in its SYN or ACK response, refer ID 1125733. -- Vectors "IPv6 fragmented" and "IPv6 atomic fragment" offloading is not working on hardware, refer ID 1167949.
VIPRION B2250 blades
None
The High-Speed Bridge (HSB) version 2.12.4.0 bitstream is available for VIPRION B2250 blades, which includes the following updates from HSB version 2.12.3.0: - Implement Request Queue Manager (RQM) Debug registers to help diagnose certain HSB-specific issues. - 'DNS malformed' DoS vector correctly handles valid DNS queries for qnames that begin with an underscore character, refer ID 1156753. - Correct server-side Window Scale behavior, refer ID 1125733. - Hardware offload is performed correctly for "IPv6 fragmented" and "IPv6 atomic fragment" vectors, refer ID 1167949.