Bug ID 1297257: Pool member Forced Offline then Enabled is marked down on peer after Incremental sync ... When a Pool Member has been marked Forced Offline then later marked Enabled on one member of the Device Group, the Pool Member may be marked Down on Device Group members other than the member where the Pool Member was marked Enabled. ... On the BIG-IP system (Device Group member) where the Pool Member was marked Enabled, the Pool Member's status will be marked correctly according to its actual state, as determined by the Health Monitor configured for the affected Pool or Pool Member. ... Impact ... The affected pool member that may be marked Down does not receive traffic as expected as the other Device Group members. -- If the pool member is re-enabled on the Standby member, traffic on the Active member will not be sent to the pool member. -- If the pool member is re-enabled on the Active member, traffic on the Standby member will not be sent to the pool member if the Active mem...