Operational Defect Database

BugZero found this defect 359 days ago.

F5 | 1295353

The vCMP guest is not sending HTTP flow samples to sFlow receiver

Last update date:

4/26/2024

Affected products:

BIG-IP

BIG-IP vCMP

Affected releases:

14.1.5.3

14.1.5.4

14.1.5.6

15.1.8.2

15.1.9

15.1.9.1

15.1.10

15.1.10.2

15.1.10.3

15.1.10.4

16.1.3.3

16.1.3.4

Fixed releases:

No fixed releases provided.

Description:

Bug ID 1295353: The vCMP guest is not sending HTTP flow samples to sFlow receiver ... Symptoms ... The vCMP clusters without configured slot-specific management-IP addresses will report 0.0.0.0 for: sFlow (Agent Address) resulted in missing HTTP flow samples to sFlow receiver. ... Impact ... No monitoring information as there were no HTTP flow samples. ... Conditions ... - vCMP guest deployed on a chassis with only Cluster IP set, and no individual blade IP addresses configured. - Configured with an available sFlow receiver. ... Workaround ... - Configure cluster blade IP addresses. ... For example, to set the slot-specific management IP address on a vCMP guest which runs on a single slot, use a command similar to the following: tmsh modify sys cluster default members { 1 { address 198.51.100.2 } } - The HTTP flow samples will be available on a vCMP guest. ... Fix Information

Additional Resources / Links