The following error occurs which is not expected while doing tmsh load sys config default: "Invalid attempt to register an n-stage validator, the stage must be greater than the current stage, and within the range 1 to 101 inclusive, current stage: 7 registered: 5 Unexpected Error: Loading configuration process failed. , retrying 5 more times"
Getting Config error and unable to proceed with ptt tests.
In the Performance test environment, executing a script to load configs fails.
Reboot the device.
Executing tmsh load sys config fails as vlan tags are not ready by the time in R2x00/R4x00 as tenant restart solves the same.