Initializing the FIPS card for the first time which contains the FIPS firmware CNN35XX-NFBE-FW-1.1-02 may cause the below error and will not be able to initialize the card: Enter new Security Officer password (min. 0, max. 0 characters): ERROR: Too long input (max.: 0 characters) ERROR: Failed to read password ERROR: INITIALIZATION FAILED!
FIPS card cannot be used for the FIPS key traffic and will not be able to re-initialize.
First time initialization of new device with "tmsh run util fips-util -f init" command which contains the FIPS firmware CNN35XX-NFBE-FW-1.1-02