When logging Carrier Grade NAT Port Port Block Allocation (CGNAT PBA) events using NetFlow/IPFIX log destinations, if the AFM module is not enabled, the observationTimeMilliseconds Information Element value is incorrectly reported as zero in reported events.
CGNAT PBA events containing the observationTimeMilliseconds Information Element will report incorrect values for this field.
Using CGNAT PBA, logging to a NetFlow/IPFIX log destination, and AFM is not enabled.
1) Enable AFM module, or 2) Enable lsn-legacy-mode in the log profile