After upgrading, failover does not work correctly. An error is encountered in /var/log/audit/log: type=AVC msg=audit(1617263442.711:206): avc: denied { read } for pid=17187 comm="active" name="partitions" dev="dm-11" ino=259 scontext=system_u:system_r:f5config_failover_t:s0 tcontext=system_u:object_r:f5config_t:s0 tclass=dir
Failover does not complete. Floating IP addresses do not move to the active device.
-- High availability (HA) environment configured -- Devices are upgraded to version 14.1.4 -- A failover occurs
Tmsh modify sys db failover.selinuxallowscripts enable