Scenario A problem can occur when PowerEdge 14G servers are installed with default OS (RHEL/SLES) settings. Issue can also occur on non-ScaleIO Ready machines with Intel Skylake CPUs. Impact SSD performance is impacted.
Intel Skylake CPUs introduced new P-states which do not guarantee the frequency requested by the driver - hence the CPU speed can go below minimal requested, which will affect performance.
Disable C-state in the Linux kernel during boot time. For RHEL 7.2 and higher: 1) In /etc/default/grub add kernel parameters intel_idle.max_cstate= 0 processor.max_cstate= 1 intel_pstate=disable to the cmdline like: GRUB_CMDLINE_LINUX="crashkernel=auto rd.lvm.lv=rhel/root rd.lvm.lv=rhel/swap rhgb intel_idle.max_cstate= 0 processor.max_cstate= 1 intel_pstate=disable quiet" 2) Compile the new grub as follows: grub2-mkconfig -o /boot/efi/EFI/redhat/grub.cfg 3) The tuned service must disabled by typing the following. systemctl disable tuned 4) Reboot the server. See the following for more information regarding this procedure. Maximum CPU frequency is not maintained on Intel CPUs - Red Hat Customer Portal For SLES 12.2 and higher: 1) In /etc/default/grub , add the following " intel_idle.max_cstate= 0 processor.max_cstate= 1 intel_pstate=disable " to the line that starts with GRUB_CMDLINE_LINUX= For example: GRUB_CMDLINE_LINUX="intel_idle.max_cstate=0 processor.max_cstate=1 intel_pstate=disable" 2) Compile the new grub as follows: grub2-mkconfig -o /boot/efi/EFI/sles/grub.cfg 3) The tuned service does not need to be disabled like in RHEL. 4) Reboot the server. See the following for more information regarding this procedure.. Release Notes | SUSE Linux Enterprise Server 12 SP2 Impacted versions N/A - HW settings issue Fixed in version N/A
Click on a version to see all relevant bugs