In the Data Domain Operating System (DDOS), the "enclosure show summary" command displays details of the enclosures that are attached to the system. On systems that run DDOS 5.7.x or later, the command output can include non-existent enclosures in the "offline" state. The following example shows the command output: Enclosure Show Summary ---------------------- Enclosure Model No. Serial No. State OEM Name OEM Value Capacity --------- --------- -------------- ------- -------- --------- -------- 1 DD9800 NVTxxxxxxxxxxx Online 4 Slots 2 DS60 APMxxxxxxxxxxx Offline 60 Slots <=== NOTE 3 DS60 APMxxxxxxxxxxx Offline 60 Slots <=== NOTE 4 DS60 APMxxxxxxxxxxx Offline 60 Slots <=== NOTE 5 DS60 APMxxxxxxxxxxx Online 60 Slots 6 DS60 APMxxxxxxxxxxx Online 60 Slots 7 DS60 APMxxxxxxxxxxx Online 60 Slots 8 ES30 APMxxxxxxxxxxx Offline 15 Slots <=== NOTE 9 DS60 APMxxxxxxxxxxx Online 60 Slots 10 DS60 APMxxxxxxxxxxx Online 60 Slots 11 DS60 APMxxxxxxxxxxx Online 60 Slots 12 ES30 APMxxxxxxxxxxx Online 15 Slots To confirm that the non-existent enclosures are not physically attached to the DDR, run the "enclosure show topology" command. The following example shows the command output: Enclosure Show Topology ----------------------- Port enc.ctrl.port enc.ctrl.port ---- - ------------- - ------------- 2a > 9.B.H: 9.B.E > 10.B.H:10.B.E 2b > 5.B.H: 5.B.E > 11.B.H:11.B.E 2c > 7.B.H: 7.B.E 2d > 12.B.H:12.B.E 3a > 10.A.H:10.A.E > 9.A.H: 9.A.E 3b > 6.B.H: 6.B.E 3c > 7.A.H: 7.A.E 3d > 12.A.H:12.A.E 6a > 11.A.H:11.A.E > 5.A.H: 5.A.E 6b > 6.A.H: 6.A.E 6c 6d---- - ------------- - ------------- Encl WWN Serial # ---- ---------------- -------------- 5 N/A APMxxxxxxxxxxx 6 N/A APMxxxxxxxxxxx 7 N/A APMxxxxxxxxxxx 9 N/A APMxxxxxxxxxxx 10 N/A APMxxxxxxxxxxx 11 N/A APMxxxxxxxxxxx 12 N/A APMxxxxxxxxxxx Note: Enclosures 2, 3, 4, and 8 do not appear in the "enclosure show topology" output.
DDOS 5.7.x and later include a feature called "persistent enclosure ids." With the persistent enclosure ids feature, DDOS assigns a persistent enclosure ID to each storage shelf that is attached to a DDR. By default, no other storage shelf can reuse an assigned persistent enclosure ID. As a result, if a storage shelf is removed from the system, multiple commands continue to dispay the removed storage shelf in the offline state.
To remove the non-existent enclosures from the command output, perform the following steps. Important: The system reboot in step 4 shuts down and restarts the DDR. The reboot causes an outage of all services. Run the following command: #enclosure show persistent-id Verify that the non-existent enclosures are listed in the command output. An enclosure that is listed in the output has a persistent enclosure ID. If the non-existent enclosures are listed, release the persistent enclosure IDs for all enclosures: # enclosure release persistent-id all Reboot the system: # system reboot Note: During the boot process, the DDR assigns new persistent enclosure IDs to all enclosures that remain attached to the system. The non-existent enclosures are not attached to the system. Therefore, the DDR does not assign new persistent enclosure IDs to the non-existent enclosures. After the reboot, the non-sxistent enclosures no longer appear in the output of any command.
Click on a version to see all relevant bugs