The output of the Errdump reports the error message below: Switch status change contributing factor Temperature sensors: # are out of range. The output of the Tempshow shows that some sensors are in the Above maximum state: tempshow : Sensor State Centigrade Fahrenheit ID ================================================= 5 Above maximum 63 145 8 Above maximum 62 143
The following conditions can cause these error messages: A temperature issue in the data Center A temperature issue in or around the rack where the switch is installed A communication issue on the I2C bus. In this case, the error messages are false alerts and do not indicate an actual temperature issue.
If the data center does not have temperature issues, perform the followinf action based on the switch type. Departmental switch: Schedule a time to run the following command: hareboot Director switch: Schedule a time to run the follwing command: hafailover