In the Dell Automation Platform Orchestrator, under Inventory > Infrastructure >[Node Name] > Hardware > Properties, the firmware bundle Version shows either Unknown or the incorrect version after the correct firmware bundle is applied.In this instance, the Node is an XR5610. The node has a HBA355i as its drive controller.
The NativeEdge firmware bundles for 4.1 and 4.2 do not contain the HBA355i firmware release. This causes the unknown message in the user interface (UI)
Open a Service Request (SR) with Dell Support for assistance to address this issue.