BMR restore wizard (WinPE ISO) does not display all registered hosts. Only the first 100 hosts are shown in the UI. Unable to select the intended client for DR restore. Observed on PowerProtect Data Manager versions 19.20 and 19.21 with FSAgent versions 19.20 and 19.21. Applies to: PowerProtect Data Manager 19.20 PowerProtect Data Manager 19.21 FSAgent 19.20 FSAgent 19.21
The BMR wizard enforces a default pagination limit of 100 hosts. When the number of registered clients exceeds this threshold, additional hosts are not displayed, preventing selection for restore.
Upgrade both PowerProtect Data Manager and FSAgent to version 19.22 or later. This resolves the pagination limitation and allows full host visibility during BMR restore. Workaround If an upgrade is not immediately possible: Contact Dell Support to apply a patch or workaround for this issue. Reference this article number 000387314 to expedite resolution.