Replication over a high-bandwidth, high-latency network is slow High replication lag Default replication settings do not achieve expected throughput Applies To: All Data Domain systems using replication
Default network parameters are optimized for: Low-latency local networks (such as, <1 ms RTT) Moderate WAN latency (up to 50–100 ms) For high-bandwidth, high-latency links , the default settings underutilize available bandwidth because acknowledgments take longer to return, limiting throughput.
Step 1: Calculate Bandwidth-Delay Product. The bandwidth-delay product determines how much data can be in transit before acknowledgments return. Formula: Bandwidth (Bytes/sec) × Delay (seconds) = Bandwidth-Delay Value If the value exceeds 100,000 bytes , tuning replication options can improve performance. Step 2: Measure Bandwidth Use iperf on both source and destination Data Domain systems: Destination (server mode): # net iperf server Source (client mode): # net iperf client <destination IP> duration 30 interval 3 nodelay Convert the result from Mbits/sec to Bytes/sec: Example: 4.92 Mbits/sec = (4,920,000 ÷ 8) = 615,000 Bytes/sec Step 3: Measure Delay Use net ping from source DD: # net ping <destination IP> path-mtu do packet-size 1472 count 5 Example output: time=173 ms → Delay = 0.173 seconds Step 4: Compute Bandwidth-Delay 615,000 Bytes/sec × 0.173 sec = 106,395 Bytes (~106 KB) Since this exceeds 100,000, tuning is recommended. Step 5: Configure Replication Options. Disable replication: # replication disable all # replication status Wait until the status shows disconnected . Set bandwidth: # replication option set bandwidth 615000 Set delay: # replication option set delay 173 Restart filesystem: # filesys restart Re-enable replication: # replication enable all Tip: Set replication throttle to 90–95% of link bandwidth for best results. Undo Changes | Reset to Default: # replication disable all # replication option reset bandwidth # replication option reset delay # filesys restart # replication enable all
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.