The specific port range goes into "hw_Failure" state: `show interface brief` ----------------------------------------------------------------------------------------- Interface Vsan Admin Admin Status SFP Oper Oper Port Logical Mode Trunk Mode Speed Channel Type Mode (Gbps) ----------------------------------------------------------------------------------------- fc9/41 1400 FX off hwFailure swl -- -- -- -- fc9/42 1400 FX off hwFailure swl -- -- -- -- fc9/43 1400 FX off hwFailure swl -- -- -- -- fc9/44 1400 FX off hwFailure swl -- -- -- -- fc9/45 1 FX off hwFailure swl -- -- -- -- fc9/46 1 FX off hwFailure swl -- -- -- -- fc9/47 1400 FX off hwFailure swl -- -- -- -- fc9/48 1 E on hwFailure swl -- -- 57 -- The error code is seen in the module internal exception log as below: `show module internal exceptionlog module 9` ********* Exception info for module 9 ******** exception information --- exception instance 1 ---- Module Slot Number: 9 Device Id : 204 Device Name : F16 Generic Driver Device Errorcode : 0xccc05600 Device ID : 204 (0xcc) Device Instance : 05 (0x05) Dev Type (HW/SW) : 06 (0x06) ErrNum (devInfo) : 00 (0x00) System Errorcode : 0x42b8001e fatal error Error Type : FATAL error PhyPortLayer : Fibre Channel Port(s) Affected : fc9/41-48 Error Description : F16_PLDA_RETRY_MERR DSAP : 0 (0x0) Time : Mon Jan 6 22:22:32 2025 (Ticks: 677CAC08 jiffies) A module reset is seen in the show logging nvram: `show logging nvram` 2025 Jan 6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600) 2025 Jan 6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE `show logging log` 2025 Jan 6 22:22:32 WTXA19710H15 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 9 (Serial number: JAE18280N1K) reported failure on ports fc9/41-48 (Fibre Channel) due to fatal error in device DEV_F16_CMN (device error 0xccc05600) 2025 Jan 6 22:22:32 WTXA19710H15 %PORT-CHANNEL-5-PORT_DOWN: port-channel57: fc9/48 is down 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/48 is down (Hardware Failure) port-channel57 ISL to WTXA19710C02 fc7/22 2025 Jan 6 22:22:33 WTXA19710H15 %CALLHOME-2-EVENT: PORT_FAILURE 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/47 is down (Hardware Failure) ltx15brwccas01_h0 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/46 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1%$ Interface fc9/45 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/44 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/43 is down (Hardware Failure) 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/42 is down (Hardware Failure) ltx14brwccas02_h0 2025 Jan 6 22:22:33 WTXA19710H15 %PORT-5-IF_DOWN_HW_FAILURE: %$VSAN 1400%$ Interface fc9/41 is down (Hardware Failure) ltx14brwccas01_h0
The DEV_F16_CMN error on a Cisco MDS 9000 series switch typically indicates a hardware issue related to the F16 ASIC. This error often results in the module rebooting due to an unrecoverable multi-bit Error-Correcting Code (ECC) error.
The only way to recover an interface from hw_Failure is to disruptively reload the module. #reload module x If the interfaces are in a temporary hardware failure, status is recoverable by module reload. If the interfaces have a permanent hardware failure, then proceed with module replacement. WARNING: The activity is disruptive and should be performed during the maintenance window.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.