Screenshot from the PFxM UI showing that the block-legacy-gateway is missing data for required field: Fault Set 1. (VXFM00215) Impact Unable to add volume via the resource group.
A rare race condition may occur during a resource group deployment, where the gateway's attempt to inventory the PowerFlex system fails, leading to missing database objects for the block gateway.
From the PFxM UI Resource group, perform an Update Resource Group Details (URGD) operation. This will update the database with the appropriate settings. Once this operation is complete, attempt the Add Volume operation. Impacted Versions PFMP 4.x Fixed In Version PFMP 4.8