-- Existing client: admin@Lab-AVE:~/>: mccli client show --recursive |grep w11d15 clientname.some.company.com /clients Normal -- Group properly configured to use specific dataset: admin@Lab-AVE:~/>: mccli group show --name=/clients/Backup_Bol_Weekly |egrep "Attrib|---|Name|Type|Dataset" Attribute Value ------------------------ ----------------------- Name Backup_Bol_Weekly Type Normal Dataset /Backup_Bol <--<-- Chosen dataset -- Dataset configured to use specific Plugin: admin@Lab-AVE:~/>: mccli dataset show --name=/Backup_Bol |egrep "Value|Name|ID" |sort -u Attribute Value ID 1684319635113 <--<-- Dataset ID number Name Backup_Bol Windows File System Target ID 3001 <--<-- Plugin in use on this dataset -- Dataset being used instead (on this particular example), when the backup is started: admin@Lab-AVE:~/>: mccli dataset show --name=/BkpBol_VSS_Only |egrep "Value|Name|ID" |sort -u Attribute Value ID 1693415871568 <--<-- Dataset ID number Name BkpBol_VSS_Only Windows VSS Target ID 3015 <--<-- Plugin in use on this dataset -- Backup in progress, using the "wrong dataset" (reduced command output to show the group, Plug-in, and dataset information since that info is in the far-right portion of the complete output) - Same information can be seen in the Activity window in the AUI or Administration GUI: admin@Lab-AVE:~/>: mccli activity show --name=/clients/clientname.some.company.com --verbose 0,23000,CLI command completed successfully. Status Start Time Client Domain Group Plug-In Dataset -------------- -------------------- ---------------------------- -------- -------------------------- ----------- ---------------- Waiting-Client 2023-08-30 15:26 BRT clientname.some.company.com /clients /clients/Backup_Bol_Weekly Windows VSS /BkpBol_VSS_Only <--<-- -- The backup started may end up with the status "No Data"
-- The option "Override dataset" is enabled. -- Option is seen under "Backup Policy" in the Avamar AUI -- While in the Avamar Administration UI the same option is under "Edit Client" Review a similar issue found in KB: Avamar: Backup Fails with No Data Status - Unable to Determine Plugin Version -- Example of a backup client with the override dataset enabled (this is the root cause for the "wrong dataset" in use despite of group and dataset properly configured - dataset applied in the override lists its ID number only, not the dataset name): admin@Lab-AVE:~/>: mccli client show --name=/clients/clientname.some.company.com |egrep "Value|---|Fully|Group" |head -5 Attribute Value ------------------------ ------------------------------------------------------------- Fully Qualified Name /clients/clientname.some.company.com Override Group Retention No Member of Group /clients/Backup_Bol_Weekly (Override Dataset: 1693415871568) <-- -- Example of a backup client with the override dataset disabled (the expected result of this article): admin@Lab-AVE:~/>: mccli client show --name=/clients/clientname.some.company.com |egrep "Value|---|Fully|Group" |head -5 Attribute Value ------------------------ ------------------------------------------------------ Fully Qualified Name /clients/clientname.some.company.com Override Group Retention No Member of Group /clients/Backup_Bol_Weekly
How to Enable or Disable Override Dataset in Avamar. Option 1: Avamar AUI Navigate to Backup Policy: Go to Backup Policy in the Avamar AUI. Select the domain where the Backup Policy resides. Edit the Backup Policy: Click the Backup Policy that you want to modify. Click EDIT . Proceed to Summary: Click NEXT on each screen until you reach the Summary page. On the bottom-right corner, the button changes from NEXT to FINISH . Set Override Dataset: Scroll to the bottom of the Summary page. Under Override Dataset , choose: Blank (to disable override), or The wanted dataset (to enable override). Save Changes: Click FINISH . Option 2: Avamar Administration UI Navigate to Policy: Go to Policy in the Avamar Administration UI. Select Clients . Select and Edit Client: Choose the client that you want to modify. Click Edit . Go to Groups Tab: Open the Groups tab. Set Override Dataset: Under Override Dataset , choose: Blank (to disable override), or The wanted dataset (to enable override).
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.