Loading...
Loading...
The FLR fails with the following error: Unable to remove NFS export at 'nwrsvr:/data/col1/vpdevice01/FLR-ABC001-cd876cd4-80cd-4c79-890d-7526fb03cab2': Unable to run SSH command, error Unable to get command output of 'nfs del "/data/col1/vpdevice01/FLR-ABC001-cd876cd4-80cd-4c79-890d-7526fb03cab2" ', error Process exited with: 34. Reason was: () 159373:nsrvproxy_flr: vProxy Log: 2020-11-08T13:48:35Z ERROR: [99] Unable to create datastore 'EMC-FLR-ABC001-1603427832' using 'nwrsvr:/data/col1/vpdevice01/FLR-ABC001-cd876cd4-80cd-4c79-890d-7526fb03cab2': ServerFaultCode: An error occurred during host configuration. NFS mount nwrsvr:/data/col1/vpdevice01/FLR-ABC001-cd876cd4-80cd-4c79-890d-7526fb03cab2 failed: NFS has reached the maximum number of supported volumes.
The number of NFS volumes mounted on the ESXi host has reached the maximum limit.
Reconfigure the maximum number of NFS volumes that can be mounted by resetting the NFS under Advanced Settings on the ESXi host. For detailed instructions, refer to the following VMware KB article: https://kb.vmware.com/s/article/1020652