This alert pertains to VMware SRM and Dell Storage Manager (DSM) . It contains specific information related to system features and functionality. Alert: A re-protect operation in VMware SRM may fail. This failure occurs when the DR is activated in Dell Storage Manager and a remote data collector is used. The following error message appears: Failed to reverse replication for device X Cause: SRA command reverseReplication failed for device X Cause: Error starting a replication [SN : X][Error the destination Volume : [Name : Volume Name] does not have a replay in common with the source volume] When the DR is activated, the system creates a new restore point labeled " Repl of restore point ." The system should remove the original restore point at this time. The system does not remove the original restore point. Affected versions: Dell Storage Manager versions 2016 R1.1 and 2016 R2.1 and Dell Enterprise Manager 2015 R3.1
N/A
Workaround: Before you initiate an SRM re-protect, complete the following steps: Connect to the primary data collector. Delete the original restore point. Validate and save the restore points. Refresh the SRM array pairs. Resolution: Dell Storage Manager 2016 R3.1 resolves this issue.