Loading...
Loading...
The vendor has published 1 unique mention(s) for this bug: 1. When you upgrade to NetScaler 14.1-56.x, if the folder /var/mps/db_pgsql/data/pg_wal is a symbolic link, then the configuration migration fails. As a result, the system starts with the default configuration instead of retaining the existing settings. The issue is caused by the older database failing to start due to a missing directory. Modules: 1. Infrastructure Latest urls for this bug: 1. https://docs.netscaler.com/en-us/updates?product=NetScaler%20Console%20on-prem%20%28ADM%29&version=13.1&build=62.27 2. https://docs.netscaler.com/en-us/updates?product=NetScaler%20Console%20on-prem%20%28ADM%29&version=14.1&build=60.57
Click on a version to see all relevant bugs
Citrix NetScaler Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.