The vendor has published 1 unique mention(s) for this bug: 1. In NetScaler High Availability (HA) deployments on cloud platforms, HA recovery remains incomplete after a split-brain resolution. The services are disrupted because cloud resources stay with the secondary node even after the primary resumes its role. This issue occurs because after split-brain recovery primary node is not alerted to reclaim cloud resources. Modules: 1. Platform Latest urls for this bug: 1. https://docs.netscaler.com/en-us/updates?product=NetScaler%20ADC%20%28includes%20NetScaler%20Gateway%29&version=14.1 FIPS&build=66.68 2. https://docs.netscaler.com/en-us/updates?product=NetScaler%20ADC%20%28includes%20NetScaler%20Gateway%29&version=14.1&build=51.80 3. https://docs.netscaler.com/en-us/updates?product=NetScaler%20ADC%20%28includes%20NetScaler%20Gateway%29&version=14.1&build=56.74 4. https://docs.netscaler.com/en-us/updates?product=NetScaler%20ADC%20%28includes%20NetScaler%20Gateway%29&version=14.1&build=66.59