The vendor has published 1 unique mention(s) for this bug: 1. The GSLB service state might differ between the primary and backup sites when the load balancing virtual server fails at the child site. This discrepancy arises from a race condition between the MEP update from the GSLB site and the monitor probe, specifically when the trigger monitor is configured as MEPDOWN. Modules: 1. Load Balancing Latest urls for this bug: 1. https://docs.netscaler.com/en-us/updates?product=NetScaler%20ADC%20%28includes%20NetScaler%20Gateway%29&version=13.1&build=54.29 2. https://docs.netscaler.com/en-us/updates?product=NetScaler%20ADC%20%28includes%20NetScaler%20Gateway%29&version=13.1&build=56.18 3. https://docs.netscaler.com/en-us/updates?product=NetScaler%20ADC%20%28includes%20NetScaler%20Gateway%29&version=14.1&build=38.53