OPERATIONAL DEFECT DATABASE
...

...
Symptom ======== Polling the disabled Bluetooth0/4 interface on 17.12.2 via snmp, after a "wr erase" and re-enabling snmp, fails to return any data. This differs from the behavior seen on 17.9.2 where we can poll the same disabled Bluetooth0/4 interface successfully after a "wr erase" Example: 17.12.2 ======= - after "wr erase" and re-enabling snmp, polling the disabled Bluetooth0/4 fails Switch#show running-config interface bluetooth 0/04 Building configuration... Current configuration : 5 bytes end Switch#snmp get v2c x.x.x.x vrf Mgmt-vrf TEST oid ifAdminStatus.2 ifDescr.2 <<<<<<This fails SNMP Response: reqid 1, errstat 0, erridx 0 ifAdminStatus.2 = NO_SUCH_INSTANCE_EXCEPTION ifDescr.2 = NO_SUCH_INSTANCE_EXCEPTION Switch# 17.9.2: ======== - after "wr erase" and re-enabling snmp,Bluetooth0/4 interface is disabled, but we can poll it successfully Switch#show running-config interface bluetooth 0/04 Building configuration... Current configuration : 5 bytes end Switch#snmp get v2c x.x.x.x vrf Mgmt-vrf TEST oid ifAdminStatus.2 ifDescr.2 SNMP Response: reqid 2, errstat 0, erridx 0 ifAdminStatus.2 = 2 ifDescr.2 = Bluetooth0/4 <<<<<<< works as expected
Cat9k switch on 17.12.2 with bluetooth0/4 interface disabled
Enable the bluetooth0/4 interface
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.