The current implementation of syslog in NX-OS does not follow RFC 5424. In the versions, NXOS 9.3(7a), 9.3(10), 9.3(13), 10.2(4), and 10.3(4a), the implementation of syslog does not follow RFC 5424. The timestamp of the syslog using RFC is not correct. It uses the system clock's magnitude and Z without considering the offset. For example, if the system clock is 15:32:32.520 CET. The Syslog will contain "15:32:10.42Z", interpreted as 15:32:10.42 UTC. F241.01.18-C93180YC-1(config-if)# show logg log duration 0:1:0 1 2024-02-07T15:32:10.42Z F241.01.18-C93180YC-1 %ETHPORT-5-IF_ADMIN_UP: Interface Ethernet1/1 is admin up. F241.01.18-C93180YC-1(config-if)# show clock Warning: No NTP peer/server configured. Time may be out of sync. 15:32:32.520 CET Wed Feb 07 2024 Time source is NTP
Having configured: - clock timezone CET 1 0 - logging rfc-strict 5424
There is no workaround