OPERATIONAL DEFECT DATABASE
...

...
Ap will not remain joined to the controller After joining the controller getting 2023/12/06 19:12:08.571796429 {wncd_x_R0-0}{1}: [apmgr-ap-global] [20151]: (note): MAC: 588b.1ce5.3530 BSSID Plumb : Success. Slot : 2, BSSIDX : 2, IFID : 90000609 2023/12/06 19:12:08.572048563 {cpp_cp_F0-0}{1}: [errmsg] [20446]: (ERR): %CPPOSLIB-3-ERROR_NOTIFY: F0/0: cpp_cp_svr: cpp_cp encountered an error -Traceback= 1#938061e35a53d8b26d9b99ac01aa8e29 errmsg:7FD76AB56000+E9A cpp_common_os:7FD7706D0000+1E42C cpp_common_os:7FD7706D0000+141BE cpp_wireless_svr_lib:7FD7724F3000+1DE86 cpp_wireless_svr_lib:7FD7724F3000+1D48C cpp_wireless_svr_smc_lib:7FD7724C4000+6B2E cpp_common_os:7FD7706D0000+222B0 cpp_common_os:7FD7706D0000+229A3 evlib:7FD76E18D000+8F67 evlib:7FD76E18D000+9CD0 cpp_common_os:7FD7706D0000+24402 :556A76D80000+3EF35 c:7FD764790 2023/12/06 19:12:08.575260080 {wncd_x_R0-0}{1}: [apmgr-db] [20151]: (ERR): 588b.1ce5.3530 Received CAPWAP tunnel NACK with reason code: IFID: 0x0 exists for ap: 588b.1ce3.4760 2023/12/06 19:12:08.575261918 {wncd_x_R0-0}{1}: [apmgr-db] [20151]: (note): MAC: 588b.1ce5.3530 CAPWAP tunnel nack handler : Closing capwap session. 2023/12/06 19:12:08.575293838 {wncd_x_R0-0}{1}: [capwapac-smgr-sess-fsm] [20151]: (note): Mac: 588b.1ce5.3530 Session-IP: 10.8.119.245[5272] 10.31.24.10[5246] Last Control Packet received 0 seconds ago. 2023/12/06 19:12:08.575312892 {wncd_x_R0-0}{1}: [capwapac-smgr-sess-fsm] [20151]: (note): Mac: 588b.1ce5.3530 Session-IP: 10.8.119.245[5272] 10.31.24.10[5246] Last Data Keep Alive Packet received 0 seconds ago. 2023/12/06 19:12:08.575313468 {wncd_x_R0-0}{1}: [capwapac-smgr-sess-fsm] [20151]: (note): Mac: 588b.1ce5.3530 Session-IP: 10.8.119.245[5272] 10.31.24.10[5246] AP disconnect reason not updated
Stale entries found Object identifier: 2634375 Description: CAPWAP 0x90000d2a Status: Done Object identifier: 3426607 Description: CAPWAP 0x90000b4d Status: Done Object identifier: 3456422 Description: CAPWAP 0x91000a84 Status: Done
Manually remove the Ap stale entries / reload the controller
Issue seen with stale capwap objects in data plane.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.