The following policy- map cannot be delete from configuration. policy-map port_child_policy class non-client-nrt-class bandwidth remaining ratio 10
Trying to remove policy-map port_child_policy will result on the following logs: BGL18-4.J.13-C9300-2(config)#no policy-map port_child_policy Oct 26 02:22:18.025: This policy-map deletion NOT allowed BGL18-4.J.13-C9300-2(config)# policy-map port_child_policy BGL18-4.J.13-C9300-2(config-pmap)#no Class non-client-nrt-class Remove class non-client-nrt-class from policy port_child_policy is not allowed.
No workaround found
Issue has been reproduced in 17.6.3, 17.6.5 and 17.9.4