OPERATIONAL DEFECT DATABASE
...

...
when configuring "link loopback" on physical port of N3548, observe the following errors: N3K-C3548-9x(config-if)# link loopback Internal error during command execution (11 8b) 2023 Aug 15 19:55:55 N3K-C3548-9x %VSHD-2-VSHD_SYSLOG_EOL_ERR: EOL function pm_cli_ethpm_set_port_config from library libpmcli_eth.so exited due to Signal 11 2023 Aug 15 19:56:06 N3K-C3548-9x %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 25921 with message vsh.bin(non-sysmgr) crashed, core will be saved . 2023 Aug 15 20:06:11 N3K-C3548-9x %VSHD-2-VSHD_SYSLOG_EOL_ERR: EOL function pm_cli_ethpm_set_port_config from library libpmcli_eth.so exited due to Signal 11 2023 Aug 15 20:08:57 N3K-C3548-9x %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 27292 with message vsh.bin(non-sysmgr) crashed, core will be saved . 2023 Aug 15 20:56:25 N3K-C3548-9x %VSHD-2-VSHD_SYSLOG_EOL_ERR: EOL function pm_cli_ethpm_set_port_config from library libpmcli_eth.so exited due to Signal 11 2023 Aug 15 20:57:46 N3K-C3548-9x %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 32605 with message vsh.bin(non-sysmgr) crashed, core will be saved .
-3548 switch -configuring "link loopback" on a physical interface This fix is applicable for all n9k platform.
none known at this time