Symptom
1
SMU install fails with reason :
FAILED: Improper State./bootflash/.smu.bin not present. Please restore file for stability.
2
The following log is observed in console at WLC start:
%BOOT-3-BOOTTIME_SMU_MISSING_DETECTED: R0/0: install_engine: SMU file /bootflash/.smu.bin missing and system impact will be unknown
Conditions
9800 WLC.
SMU.bin file deleted without the use of "install remove" command
Workaround
To avoid this state:
1
Use install deactivate / commit / remove procedure if WLC should stay in same code
2
If WLC is to be upgraded from CCO + SMU (x) -->. CCO ( y), perform the upgrade and once WLC running in CCO (y) perform install remove file SMU(y)-filename
If already on this state:
clear install state <<--- WLC will request a reboot
Further Problem Description