Information for SATA model SAMST128G3FEITL29 is missing from output of show hw-module fpd command sysadmin-vm:0_RP0# show hw fpd Mon Jul 17 00:21:00.388 UTC+00:00 FPD Versions ============== Location Card type HWver FPD device ATR Status Run Programd ----------------------------------------------------------------------------------- 0/RP0 N540-24Z8Q2C-M 1.1 Bootloader CURRENT 1.16 1.16 0/RP0 N540-24Z8Q2C-M 1.1 CPU-IOFPGA CURRENT 0.10 0.10 0/RP0 N540-24Z8Q2C-M 1.1 MB-IOFPGA CURRENT 0.27 0.27 0/PM0 N540-PWR400-A 1.256 LIT-PriMCU-ACFW CURRENT 0.04 0.04 0/PM0 N540-PWR400-A 1.256 LIT-SecMCU-ACFW CURRENT 0.07 0.07 0/PM1 N540-PWR400-A LIT-PriMCU-ACFW NOT READY 0/PM1 N540-PWR400-A LIT-SecMCU-ACFW NOT READY sysadmin-vm:0_RP0# show smart-monitor Mon Jul 17 00:21:08.463 UTC+00:00 ======== SmartCtl info for sda ======== smartctl 7.1 2021-03-08 r5212 [x86_64-linux-5.4.142-yocto-standard] (local build) Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SAMST128G3FEITL291 Serial Number: STP25270124 Firmware Version: FW1241
NCS540 with SATA model:SAMST128G3FEITL291 have impacted. Tested impacted PID: N540-24Z8Q2C-M N540-ACC-SYS
SMU request.
NA
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.