When trying to activate a Correlation Policy, sometimes the GUI shows the change, but after reloading the GUI the state of said policy goes back to disabled. Another behavior seen is that the GUI fails with the message "Couldn't activate policy". Messages log will show the following output: HTTP: 06-21 21:51:09 .502642 2023] [cgi:error] [pid 36816:tid 23352764241664] [client 10.64.99.68:20353] AH01215: : /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi HTTP: 06-21 21:51:09 .502701 2023] [cgi:error] [pid 36816:tid 23352764241664] [client 10.64.99.68:20353] AH01215: Use of uninitialized value within %err_en in concatenation (.) or string at /usr/local/sf/lib/perl/5.24.4/SF/Remediation/Util.pm line 73.: /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi HTTP: 06-21 21:51:09 .502721 2023] [cgi:error] [pid 36816:tid 23352764241664] [client 10.64.99.68:20353] AH01215: Forcibly overridding previous revision: /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi HTTP: 06-21 21:51:09 .502734 2023] [cgi:error] [pid 36816:tid 23352764241664] [client 10.64.99.68:20353] AH01215: (Couldn't activate policy:: /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi <<<< HTTP: 06-21 21:51:09 .502782 2023] [cgi:error] [pid 36816:tid 23352764241664] [client 10.64.99.68:20353] AH01215: ) in /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi:292 at /usr/local/sf/lib/perl/5.24.4/SF.pm line 120.: /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi HTTP: 06-21 21:51:09 .502825 2023] [cgi:error] [pid 36816:tid 23352764241664] [client 10.64.99.68:20353] AH01215: Use of uninitialized value in split at /usr/local/sf/lib/perl/5.24.4/SF/Synchronize.pm line 2298.: /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi HTTP: 06-21 21:51:09 .502872 2023] [cgi:error] [pid 36816:tid 23352764241664] [client 10.64.99.68:20353] AH01215: Use of uninitialized value $dateString in index at /usr/local/sf/lib/perl/5.24.4/SF/Synchronize.pm line 2333.: /usr/local/sf/htdocs/rna_policy/rna_policy_creation.cgi
FMC 4600, firmware version 7.0.5
Change permission of /etc/sf/remediation/binding.conf to www via expert mode: root@FTD# cd /etc/sf/remediation/ root@FTD# chown www:www binding.conf root@FTD# ls -l Verify the owner has changed to www
N/A