Following log message in seen on ASR9K router on running show drops location on LightSpeed or LightSpeed Plus card: LC/0/2/CPU0:Feb 30 11:00:00.000 UTC: npu_server_lsp[246]: %SYSDB-BAG-7-INTERNAL : The bag infrastructure has encountered an error. Major version conflict: got 2, expecting 1 (l2rm_show_hw_block_st) : npu_server_lsp : (PID=4946) : -Traceback= 7fb1026dd710 7fb1026dc381 7fb1026da461 556f5ceeb0c0 556f5ceeac10 7fb0f62bf1ae 7fb10e3993e3 7fb10e396c31 7fb10e3a8ecc 7fb10e3a6cd5 7fb10eefd46c 7fb10ef06f18 556f5ceafdb7 ++++++ show drops location 0/2/CPU0 [11:00:00.000 UTC Thu Feb 30 2023] +++++++ Could not access data: node 0/2/CPU0, item show/4/a/0 ('bag' detected the 'fatal' condition 'An irresolvable version conflict prevented the specified bag from being decoded') ------ show drops location 0/2/CPU0 [11:00:01.000 UTC Thu Feb 30 2023] -------
Below two conditions must be met to hit this defect: 1. ASR9K router running with fix or SMU for CSCwe25119. 2. show drop location or show drop l2rm location command is run on LightSpeed or LightSpeed Plus line card.
show drops location displays cumulative output from NP, FIA, L2RM modules. They could be obtained via below commands, 1. FIA: show drops fia location 2. NP: show drops np location . 3. L2RM: show controllers asic LS-NP instance 51 registers loc | in actCntMem0mruPortCntRclr show controllers asic LS-NP instance 51 registers loc | in actCntMem0policyDenyCntRclr
Log may be seen while collecting show tech-support np, as this show tech collects show drop location .
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.