OPERATIONAL DEFECT DATABASE
...

...
ENV LED lit as amber even if all the FAN and PSU are operational. All fans and PSUs are shown as OK in the output of the `show environment` command. In the output of the `show system internal platform all` command, the LED status are as follows. All fans are running in normal speed shown in `show env fan detail` ChassisLEDs: TOR=Green, Env=Amber, PS=Green, Fan=Amber TORLEDs: Status=Green
Issue can be reproduced on N9K-C93240YC-FX2 with 10.3(1), 10.3(2), 10.3(3).
None
The issues were caused by Code-sync damage. The number of fans were not set correctly on N9K-C93240YC-FX2 causing wrong setting of ENV LED. Fix has been added to correct the number of fans on the switch.