Symptom
- inconsistent TRK license consumption between -TR and -SE line cards on ASR-9010 router.
- There is no impact, but we need to check and address the issue to see if this is by design or a potential bug to fix it.
Conditions
issue related to IOS-XR version 7.4.2. Specifically, there are some inconsistencies with the FCM tracking license on the FLEX TR line card.
If FLEX-TR or FLEX-SE, the router should ask: A9K-4GH-FLEX-TRK, it seems only ask A9K-4GH-FLEX-TRK if the FLEX-SE is present.
Or maybe is per design, router will only ask for FLEX-SE .
ABR21:
RP/0/RSP0/CPU0#sh license summary
Tue May 9 11:27:47.336 WEST
Smart Licensing is ENABLED
Registration:
Status: REGISTERED
Smart Account: nos.pt
Virtual Account: ASR9K_LAB
Export-Controlled Functionality: ALLOWED
Last Renewal Attempt: SUCCEEDED
Next Renewal Attempt: Oct 09 2023 17:01:51 WEST
License Authorization:
Status: AUTHORIZED
Last Communication Attempt: SUCCEEDED
Next Communication Attempt: May 14 2023 11:23:23 WEST
License Usage:
License Entitlement Tag Count Status
-----------------------------------------------------------------------------
ASR 9000 3rd Generat... (A9K-24X10GE-1G-TRK) 1 AUTHORIZED
ASR 9000 3rd Generat... (A9K-MOD200-TRK) 2 AUTHORIZED
ASR 9000 20 ports 10... (A9K-MPA-20X10G-TRK) 1 AUTHORIZED
ASR 9000 400G Flexib... (A9K_4HG_FLEX_TRK) 1 AUTHORIZED -> only ask 1 (SE)
RP/0/RSP0/CPU0#sh platform
Tue May 9 11:27:50.408 WEST
Node Type State Config state
--------------------------------------------------------------------------------
0/RSP0/CPU0 A9K-RSP880-TR(Active) IOS XR RUN NSHUT
0/FT0 ASR-9010-FAN-V2 OPERATIONAL NSHUT
0/FT1 ASR-9010-FAN-V2 OPERATIONAL NSHUT
0/0/CPU0 A9K-MOD200-TR IOS XR RUN NSHUT
0/0/0 A9K-MPA-20X1GE OK
0/0/1 A9K-MPA-20X1GE OK
0/1/CPU0 A9K-MOD200-TR IOS XR RUN NSHUT
0/1/0 A9K-MPA-20X10GE OK
0/2/CPU0 A9K-4HG-FLEX-SE IOS XR RUN NSHUT
0/4/CPU0 A9K-24X10GE-1G-TR IOS XR RUN NSHUT
0/5/CPU0 A9K-4HG-FLEX-TR IOS XR RUN NSHUT
0/PT0 A9K-DC-PEM-V2 OPERATIONAL NSHUT