When running multiple iterations of show routing hash on a Cisco Nexus C3408-S switch on Cisco NX-OS Release 9.3(8) or 9.3(11), messages such as Failed to get hashing result and route not found due to innusd crash are noticed and result in device reload.
N3408-S running 9.3.8 N3K# show routing hash 10.195.77.209 10.239.89.22 ip-proto 16 vrf test Load-share parameters used for software forwarding: load-share mode: address source-destination port source-destination Hash for VRF "test" Hashing to path *10.178.254.89 Out Interface: Po16.40 For route: 0.0.0.0/0, ubest/mbest: 2/0 *via 10.178.254.85, [200/0], 00:13:36, bgp-65111, internal, tag 65111 *via 10.178.254.89, [200/0], 00:13:36, bgp-65111, internal, tag 65111 N3K# show routing hash 10.195.77.209 10.239.89.22 ip-proto 16 vrf test Load-share parameters used for software forwarding: load-share mode: address source-destination port source-destination Failed to get hashing result, err: 0xffffffff N3K# show routing hash 10.195.77.209 10.239.89.22 ip-proto 16 vrf test Load-share parameters used for software forwarding: load-share mode: address source-destination port source-destination Route not found
NA
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.