Link does not come up with QSFP-100G-ZR4-S transceiver, no (-40 dBm) TX power reported
- N540-24Q8L2DD-SYS or N540-28Z4C-SYS router or NCS5700 (LNT DNX devices) - QSFP-100G-ZR4-S transceiver
There is no workaround
No TX power is reported in "show controllers optics" output: RP/0/RP0/CPU0:Router#sh controllers optics 0/0/0/0 Controller State: Up Transport Admin State: In Service Laser State: On LED State: Yellow FEC State: FEC ENABLED Optics Status Optics Type: QSFP28 100G ZR4 S Wavelength = 1302.00 nm Alarm Status: ------------- Detected Alarms: LOW-RX1-PWR LOW-RX2-PWR LOW-RX3-PWR LOW-RX4-PWR LOW-TX1-PWR LOW-TX2-PWR LOW-TX3-PWR LOW-TX4-PWR LOW-TX1_LBC LOW-TX2_LBC LOW-TX3_LBC LOW-TX4_LBC LOS/LOL/Fault Status: Performance Monitoring: Disable THRESHOLD VALUES ---------------- Parameter High Alarm Low Alarm High Warning Low Warning ------------------------ ---------- --------- ------------ ----------- Rx Power Threshold(dBm) -3.0 -31.5 -6.0 -27.6 Tx Power Threshold(dBm) 8.1 -2.8 7.0 1.2 LBC Threshold(mA) 130.00 40.00 120.00 50.00 Temp. Threshold(celsius) 75.00 -5.00 70.00 0.00 Voltage Threshold(volt) 3.63 2.97 3.46 3.13 Configured Tx Power = 0.00 dBm Configured CD High Threshold = 0 ps/nm Configured CD lower Threshold = 0 ps/nm Configured OSNR lower Threshold = 0.00 dB Configured DGD Higher Threshold = 0.00 ps Polarization parameters not supported by optics Lane Laser Bias TX Power RX Power Output Frequency ---- ---------- ---------- ---------- ---------------- 0 0.0 mA -40.00 dBm -40.00 dBm N/A 1 0.0 mA -40.00 dBm -40.00 dBm N/A 2 0.0 mA -40.00 dBm -40.00 dBm N/A 3 0.0 mA -40.00 dBm -40.00 dBm N/A Temperature = 20.35 Celsius Voltage = 3.30 V
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.