Cat9200/Cat9200L non PoE variant switch (24T/48T) do not boot up after powercycle of device. Device gets in continuous boot loop. Bootup logs during Install boot : Initializing Hardware... System Bootstrap, Version 17.9.1r [FC11], RELEASE SOFTWARE (P) Compiled Thu 01/05/2023 16:43:42 by rel Current ROMMON image : Primary C9200-48T platform with 4194304 Kbytes of main memory Preparing to autoboot. [Press Ctrl-C to interrupt] 0 boot: attempting to boot from [flash:packages.conf] boot: reading file packages.conf ############## Initializing Hardware... Bootup logs during Bundle boot : Initializing Hardware... System Bootstrap, Version 17.12.1r [FC2], RELEASE SOFTWARE (P) Compiled Tue 05/23/2023 17:09:41 by rel Current ROMMON image : Primary C9200-48T platform with 4194304 Kbytes of main memory Preparing to autoboot. [Press Ctrl-C to interrupt] 0 boot: attempting to boot from [flash:cat9k_lite_iosxe.17.09.03.SPA.bin] boot: reading file cat9k_lite_iosxe.17.09.03.SPA.bin ##################################################################################################################################################### Initializing Hardware... Affected releases : 17.9.3, 17.3.7 Affected SKUs : 9200L : C9200L-24T-4G C9200L-48T-4G C9200L-24T-4X C9200L-48T-4X 9200: C9200-24T C9200-48T
Issue is observed when all the below mentioned conditions are met 1) When Cat9200/ Cat9200L non PoE Switch (Standalone or part of stack) having single 125WAC power supply in slot A with serial number starting with ARTxxxxxxxx. 2) Device is booted with IOS 17.9.3 or 17.3.7 as part of Power failure or Powercycle is done for switch
1) Boot device with IOS image not affected with this issues. For example 17.6.5 or 17.9.4 2) Move 125WAC ARTxxxxxxxx power supply present in slot A to Slot B
1. Cat9200/Cat9200L non PoE variant switch (24T/48T) device gets stuck in continuous boot loop after power failure. 2. Issue is not seen if device is booted with affected version as part of software reboot/reset. 3. issue is not seen if a powersupply populated in slot B
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.