OPERATIONAL DEFECT DATABASE
...

...
FIB HW programming error for mpls nh object with 'Entry exists' error.
1. Issue is seen in Jericho-2 based platforms with BGP LU multipath auto protect. 2. In BGP LU multipath, any transition from 2 path to 3 paths or from lower number of paths to higher paths leads to asymmetric increase in count of s/w object - mplsnh which programs the mpls encap in h/w. 3. Further when the LU prefix is withdrawn /path is going away, mpls encap is not deleted in h/w. It leads to stale mpls encap. 4. Any re-use of this encap by other features lead to failure. FIB MGR returning entry exist is one such failure.
LC reload where MPLS encap reference count mismatch has happened.
HW Programming failed for table,mplsnh, failure-reason,EntryExist syslogs RP/0/RP0/CPU0:SP-AG14-Eyrie#sh logging | i HW Wed Jan 25 18:32:33.250 +0530 LC/0/0/CPU0:Jan 25 18:25:21.210 +0530: fib_mgr[299]: %PLATFORM-PLAT_FIB-3-HW_PROG_ERROR : HW Programming failed for table,mplsnh,key,0xc0007aea05190064,unit,0,dpa_trans_id,1362794,failure-reason,EntryExist LC/0/0/CPU0:Jan 25 18:25:22.585 +0530: fib_mgr[299]: %PLATFORM-PLAT_FIB-3-HW_PROG_ERROR : HW Programming failed for table,mplsnh,key,0xc0007aea05190064,unit,0,dpa_trans_id,1365389,failure-reason,EntryExist LC/0/0/CPU0:Jan 25 18:27:36.039 +0530: fib_mgr[299]: %PLATFORM-PLAT_FIB-3-HW_PROG_ERROR : HW Programming failed for table,mplsnh,key,0xc0007aea05190064,unit,0,dpa_trans_id,1409674,failure-reason,EntryExist