OPERATIONAL DEFECT DATABASE
...

...
High number of interface input drops seen on changing/removing the policer rate.
changing/removing the policer rate.
none
RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#show interfaces tenGigE 0/0/0/0 Thu Dec 22 18:55:03.707 UTC TenGigE0/0/0/0 is up, line protocol is up Interface state transitions: 1 Hardware is TenGigE, address is 7c31.0e6d.e000 (bia 7c31.0e6d.e000) Internet address is 192.168.200.1/24 MTU 1514 bytes, BW 10000000 Kbit (Max: 10000000 Kbit) reliability 255/255, txload 0/255, rxload 18/255 Encapsulation ARPA, Full-duplex, 10000Mb/s, SR, link type is force-up output flow control is off, input flow control is off Carrier delay (up) is 10 msec loopback not set, Last link flapped 01:03:55 ARP type ARPA, ARP timeout 04:00:00 Last input 00:00:00, output 01:03:13 Last clearing of "show interface" counters 00:00:43 30 second input rate 727795000 bits/sec, 114289 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 4993718 packets input, 3974998303 bytes, 1010000 total input drops <<<< generally it is dropping 500,000 packets 0 drops for unrecognized upper-level protocol Received 0 broadcast packets, 0 multicast packets 0 runts, 0 giants, 0 throttles, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 0 packets output, 0 bytes, 0 total output drops Output 0 broadcast packets, 0 multicast packets 0 output errors, 0 underruns, 0 applique, 0 resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#show interfaces tenGigE 0/0/0/0 Thu Dec 22 18:55:13.605 UTC TenGigE0/0/0/0 is up, line protocol is up Interface state transitions: 1 Hardware is TenGigE, address is 7c31.0e6d.e000 (bia 7c31.0e6d.e000) Internet address is 192.168.200.1/24 MTU 1514 bytes, BW 10000000 Kbit (Max: 10000000 Kbit) reliability 255/255, txload 0/255, rxload 18/255 Encapsulation ARPA, Full-duplex, 10000Mb/s, SR, link type is force-up output flow control is off, input flow control is off Carrier delay (up) is 10 msec loopback not set, Last link flapped 01:04:05 ARP type ARPA, ARP timeout 04:00:00 Last input 00:00:00, output 01:03:23 Last clearing of "show interface" counters 00:00:53 30 second input rate 727836000 bits/sec, 114296 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 6125011 packets input, 4875488119 bytes, 1010000 total input drops 0 drops for unrecognized upper-level protocol Received 0 broadcast packets, 0 multicast packets 0 runts, 0 giants, 0 throttles, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 0 packets output, 0 bytes, 0 total output drops Output 0 broadcast packets, 0 multicast packets 0 output errors, 0 underruns, 0 applique, 0 resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#show interfaces tenGigE 0/0/0/0 Thu Dec 22 18:55:19.579 UTC TenGigE0/0/0/0 is up, line protocol is up Interface state transitions: 1 Hardware is TenGigE, address is 7c31.0e6d.e000 (bia 7c31.0e6d.e000) Internet address is 192.168.200.1/24 MTU 1514 bytes, BW 10000000 Kbit (Max: 10000000 Kbit) reliability 255/255, txload 0/255, rxload 18/255 Encapsulation ARPA, Full-duplex, 10000Mb/s, SR, link type is force-up output flow control is off, input flow control is off Carrier delay (up) is 10 msec loopback not set, Last link flapped 01:04:11 ARP type ARPA, ARP timeout 04:00:00 Last input 00:00:00, output 01:03:29 Last clearing of "show interface" counters 00:00:59 30 second input rate 727878000 bits/sec, 114303 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 6808081 packets input, 5419243333 bytes, 1010000 total input drops 0 drops for unrecognized upper-level protocol Received 0 broadcast packets, 0 multicast packets 0 runts, 0 giants, 0 throttles, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 0 packets output, 0 bytes, 0 total output drops Output 0 broadcast packets, 0 multicast packets 0 output errors, 0 underruns, 0 applique, 0 resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88# RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#show interfaces tenGigE 0/0/0/0 Thu Dec 22 18:55:31.304 UTC TenGigE0/0/0/0 is up, line protocol is up Interface state transitions: 1 Hardware is TenGigE, address is 7c31.0e6d.e000 (bia 7c31.0e6d.e000) Internet address is 192.168.200.1/24 MTU 1514 bytes, BW 10000000 Kbit (Max: 10000000 Kbit) reliability 255/255, txload 0/255, rxload 18/255 Encapsulation ARPA, Full-duplex, 10000Mb/s, SR, link type is force-up output flow control is off, input flow control is off Carrier delay (up) is 10 msec loopback not set, Last link flapped 01:04:23 ARP type ARPA, ARP timeout 04:00:00 Last input 00:00:00, output 01:03:41 Last clearing of "show interface" counters 00:01:11 30 second input rate 727900000 bits/sec, 114306 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 8149525 packets input, 6487029775 bytes, 1514934 total input drops <<<<<<< 500,000 increment 0 drops for unrecognized upper-level protocol Received 0 broadcast packets, 0 multicast packets 0 runts, 0 giants, 0 throttles, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 0 packets output, 0 bytes, 0 total output drops Output 0 broadcast packets, 0 multicast packets 0 output errors, 0 underruns, 0 applique, 0 resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88# RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#show interfaces tenGigE 0/0/0/0 Thu Dec 22 18:55:35.758 UTC TenGigE0/0/0/0 is up, line protocol is up Interface state transitions: 1 Hardware is TenGigE, address is 7c31.0e6d.e000 (bia 7c31.0e6d.e000) Internet address is 192.168.200.1/24 MTU 1514 bytes, BW 10000000 Kbit (Max: 10000000 Kbit) reliability 255/255, txload 0/255, rxload 18/255 Encapsulation ARPA, Full-duplex, 10000Mb/s, SR, link type is force-up output flow control is off, input flow control is off Carrier delay (up) is 10 msec loopback not set, Last link flapped 01:04:27 ARP type ARPA, ARP timeout 04:00:00 Last input 00:00:00, output 01:03:45 Last clearing of "show interface" counters 00:01:15 30 second input rate 727923000 bits/sec, 114309 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 8657658 packets input, 6891475275 bytes, 1514934 total input drops 0 drops for unrecognized upper-level protocol Received 0 broadcast packets, 0 multicast packets 0 runts, 0 giants, 0 throttles, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 0 packets output, 0 bytes, 0 total output drops Output 0 broadcast packets, 0 multicast packets 0 output errors, 0 underruns, 0 applique, 0 resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88# RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#show interfaces tenGigE 0/0/0/0 Thu Dec 22 18:55:57.311 UTC TenGigE0/0/0/0 is up, line protocol is up Interface state transitions: 1 Hardware is TenGigE, address is 7c31.0e6d.e000 (bia 7c31.0e6d.e000) Internet address is 192.168.200.1/24 MTU 1514 bytes, BW 10000000 Kbit (Max: 10000000 Kbit) reliability 255/255, txload 0/255, rxload 18/255 Encapsulation ARPA, Full-duplex, 10000Mb/s, SR, link type is force-up output flow control is off, input flow control is off Carrier delay (up) is 10 msec loopback not set, Last link flapped 01:04:49 ARP type ARPA, ARP timeout 04:00:00 Last input 00:00:00, output 01:04:07 Last clearing of "show interface" counters 00:01:37 30 second input rate 727931000 bits/sec, 114311 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 11121467 packets input, 8852696894 bytes, 2019880 total input drops 0 drops for unrecognized upper-level protocol Received 0 broadcast packets, 0 multicast packets 0 runts, 0 giants, 0 throttles, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 0 packets output, 0 bytes, 0 total output drops Output 0 broadcast packets, 0 multicast packets 0 output errors, 0 underruns, 0 applique, 0 resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88# RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#rollback configuration last 1 <<<<<<< Changed the configured policer rate to 805 from 605 Mbps Thu Dec 22 18:56:11.728 UTC Loading Rollback Changes. Loaded Rollback Changes in 1 sec Committing. 1 items committed in 1 sec Updating. Updated Commit database in 1 sec Configuration successfully rolled back 1 commits. RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88# RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#show interfaces tenGigE 0/0/0/0 Thu Dec 22 18:56:20.559 UTC TenGigE0/0/0/0 is up, line protocol is up Interface state transitions: 1 Hardware is TenGigE, address is 7c31.0e6d.e000 (bia 7c31.0e6d.e000) Internet address is 192.168.200.1/24 MTU 1514 bytes, BW 10000000 Kbit (Max: 10000000 Kbit) reliability 255/255, txload 0/255, rxload 18/255 Encapsulation ARPA, Full-duplex, 10000Mb/s, SR, link type is force-up output flow control is off, input flow control is off Carrier delay (up) is 10 msec loopback not set, Last link flapped 01:05:12 ARP type ARPA, ARP timeout 04:00:00 Last input 00:00:00, output 01:04:30 Last clearing of "show interface" counters 00:02:00 30 second input rate 727944000 bits/sec, 114314 packets/sec 30 second output rate 0 bits/sec, 0 packets/sec 13779100 packets input, 10968169567 bytes, 4942923 total input drops <<< immediately it dropped around 3000,000 packets it is unexpected . 0 drops for unrecognized upper-level protocol Received 0 broadcast packets, 0 multicast packets 0 runts, 0 giants, 0 throttles, 0 parity 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored, 0 abort 0 packets output, 0 bytes, 0 total output drops Output 0 broadcast packets, 0 multicast packets 0 output errors, 0 underruns, 0 applique, 0 resets 0 output buffer failures, 0 output buffers swapped out 0 carrier transitions RP/0/RP0/CPU0:F340.13.26-NCS-55A2-A88#
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.