OPERATIONAL DEFECT DATABASE
...

...
Node uptime is incorrect as seen from ‘show logging onboard uptime’. RP/0/RSP1/CPU0:ASR-9000#run ssh rsp1_xr uptime <<<<<<<< HERE: Uptime is 7 days. Warning: Permanently added 'rsp1_xr' (ECDSA) to the list of known hosts. 09:36:41 up 7 days, 21 min, 0 users, load average: 0.09, 0.15, 0.19 sysadmin-vm:0_RSP1# show logging onboard uptime location 0/RSP1 OBFL Uptime Information For : 0/RSP1 * indicates incomplete time-sync while record was written ! indicates time reset backwards while system was running ----------------------------------------------------------------------------------- UPTIME CARD INFORMATION ----------------------------------------------------------------------------------- Entity Name : Value ----------------------------------------------------------------------------------- Previous Chassis SN : ------------ Current Chassis SN : Previous R/S/I : -/-/- Current R/S/I : 0/1/0 Write Interval : 15 (min) First Power On TS : 06/03/2022 15:49:37 Last Erase TS : --/--/---- --:--:-- Rack Change Count : 0 Slot Change Count : 0 ----------------------------------------------------------------------------------- UPTIME INFORMATION ----------------------------------------------------------------------------------- Start Time (UTC) | End Time (UTC) | Card Uptime info mm/dd/yyyy hh:mm:ss | mm/dd/yyyy hh:mm:ss | Weeks.Days.Hrs.Min.Sec ----------------------------------------------------------------------------------- 08/18/2022 09:12:24 | 08/23/2022 21:23:03 | 0.5.12.10.39 <<<<<<<< HERE: Uptime is 5 days. RP/0/RSP0/CPU0:ASR-9000#run ssh lc2_xr uptime Warning: Permanently added 'lc2_xr' (ECDSA) to the list of known hosts. 09:40:55 up 5 days, 11:55, 0 users, load average: 0.08, 0.16, 0.14 <<<<<<<< HERE: Uptime is 5 days. sysadmin-vm:0_RSP0# show logging onboard uptime location 0/2 OBFL Uptime Information For : 0/2 * indicates incomplete time-sync while record was written ! indicates time reset backwards while system was running ----------------------------------------------------------------------------------- UPTIME CARD INFORMATION ----------------------------------------------------------------------------------- Entity Name : Value ----------------------------------------------------------------------------------- Previous Chassis SN : ------------ Current Chassis SN : Previous R/S/I : -/-/- Current R/S/I : 0/4/0 Write Interval : 15 (min) First Power On TS : 10/01/2020 01:52:20 Last Erase TS : --/--/---- --:--:-- Rack Change Count : 0 Slot Change Count : 0 ----------------------------------------------------------------------------------- UPTIME INFORMATION ----------------------------------------------------------------------------------- Start Time (UTC) | End Time (UTC) | Card Uptime info mm/dd/yyyy hh:mm:ss | mm/dd/yyyy hh:mm:ss | Weeks.Days.Hrs.Min.Sec ----------------------------------------------------------------------------------- 08/19/2022 20:50:59 | 08/22/2022 01:06:53 | 0.2.4.15.54 <<<<<<<< HERE: Uptime is 2 days.
Node is running eXR version.
Correct uptime can be verified by executing 'run ssh _xr uptime'. Examples for RSP card (rsp1) and Line Card (lc2): RP/0/RSP1/CPU0:ASR-9000#run ssh rsp1_xr uptime Warning: Permanently added 'rsp1_xr' (ECDSA) to the list of known hosts. 09:36:41 up 7 days, 21 min, 0 users, load average: 0.09, 0.15, 0.19 RP/0/RSP0/CPU0:ASR-9000#run ssh lc2_xr uptime Warning: Permanently added 'lc2_xr' (ECDSA) to the list of known hosts. 09:40:55 up 5 days, 11:55, 0 users, load average: 0.08, 0.16, 0.14
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.