OPERATIONAL DEFECT DATABASE
...

...
The switch hangs when a flow monitor is modified. Following this error, the configuration cannot be saved using the 'copy run start' command. The following outputs will be seen: 2023 Jun 24 10:17:51.468376 N9504 %SYSMGR-3-CFGWRITE_SRVTIMEOUT: Service "ascii-cfg" failed to store its configuration in the timeout period 2023 Jun 24 10:17:51.468405 N9504 %SYSMGR-2-CFGWRITE_ABORTED: Configuration copy aborted. 2023 Jun 24 10:17:51.899147 N9504 %SYSMGR-3-CFGWRITE_FAILED: Configuration copy failed (error-id 0x401E0045). N9504# Show system internal mts buffer summary * recv_q: not received yet (slow receiver) * pers_q/npers_q/log_q: received not dropped (leak) node sapno recv_q pers_q npers_q log_q app/sap_description sup 306 1653 10 1 4 nfm/Nfm main SAP sup 284 0 6 0 0 netstack/TCPUDP process client MTS queue sup 76 0 0 1 1 ascii_cfg_serve/ascii_cfg_server sup 1383 0 0 4 0 svc_ifc_policye/policyelem sup 3 0 0 0 1 sysmgr/+System Manager (master)
- More than 20,000 flow scale. - Failed configuration push. Example: N9504(config)# interface Ethernet1/3 N9504(config-if)# mtu 9216 N9504(config-if)# ip flow monitor NETFLOW4-IN input >>>> The N9504 switch hangs at this point. Hitting Crtl+C returns error: Failed to collect returned stimulus
Follow these steps: 1) Save the current running config to bootflash, another local file system, or a USB drive. 2) Reload the switch using the 'reload ascii' command. 3) Use the copy command to transfer the configuration saved in Step 1 back to the running configuration. 4) Save the configuration using 'copy run start'.
Configuration database corruption will persist after reloading the device using 'reload' or upgrading to a fixed release. To prevent issues, the 'reload ascii' command must be used to rebuild the configuration database.
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.