The link doesn't come up with a 1G fiber transceiver in a 25G uplink port when one side of the link is terminated on Cat9200 or Cat9300 switches.
When a 1G fiber transceiver such as GLC-SX-MMD or GLC-LH-SMD is plugged into a 25G uplink, then the link might remain in a down/down (notconnect) state upon bootup while the remote side of the link will be in the up/up (connected) state, as desired.
No workarounds such as SFP OIR, shut/no shut helps. downgrading to a software release not affected by this defect or upgrading to a software release where this defect is addressed would be an option
PSIRT Evaluation: The Cisco PSIRT has evaluated this issue and determined it does not meet the criteria for PSIRT ownership or involvement. This issue will be addressed via normal resolution channels. If you believe that there is new information that would cause a change in the severity of this issue, please contact psirt@cisco.com for another evaluation. Additional information on Cisco's security vulnerability policy can be found at the following URL: http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html