When span destination interface goes down, the NP locks up on span source interface. Span source and destination interfaces are on different NP/LCs. monitor-session SPAN ethernet destination interface HundredGigE0/2/0/0 <<< This interface goes down ! interface HundredGigE0/2/0/0 transceiver permit pid all l2transport ! interface HundredGigE0/0/0/0 mtu 9216 service-policy output QOS carrier-delay up 3000 down 20 load-interval 30 dampening ! interface HundredGigE0/0/0/0.33 <<< This interface NP locks up ipv4 mtu 9100 ipv4 address x.x.x.x 255.255.255.252 ipv4 tcp-mss-adjust enable ipv6 mtu 9100 ipv6 address zzzz:zzzz:zzzz:zzzz::z/127 monitor-session SPAN ethernet ! load-interval 30 flow ipv4 monitor netflow_v4 sampler sample ingress flow ipv6 monitor netflow_v6 sampler sample ingress encapsulation dot1q 33 ! RP/0/RSP0/CPU0:513E-B.35-ASR-9006-AC-V2-1#LC/0/2/CPU0:Dec 2 20:30:27.584 UTC: ifmgr[216]: %PKT_INFRA-LINK-3-UPDOWN : Interface HundredGigE0/2/0/0, changed state to Down LC/0/2/CPU0:Dec 2 20:30:27.584 UTC: ifmgr[216]: %PKT_INFRA-LINEPROTO-5-UPDOWN : Line protocol on Interface HundredGigE0/2/0/0, changed state to Down LC/0/2/CPU0:Dec 2 20:30:29.015 UTC: vic_0_0[390]: %PLATFORM-VIC-4-SIGNAL : Interface HundredGigE0/2/0/0, Detected Signal failure LC/0/0/CPU0:Dec 2 20:30:39.618 UTC: pfm_node_lc[305]: %PLATFORM-NP-2-NP_DIAG : Set|prm_server_to[163922]|0x1008000| NP diagnostics warning on NP0. LC/0/2/CPU0:Dec 2 20:30:42.567 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_0_LOW_RX_POWER_ALARM : Set|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 LC/0/2/CPU0:Dec 2 20:30:42.567 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_1_LOW_RX_POWER_ALARM : Set|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 LC/0/2/CPU0:Dec 2 20:30:42.567 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_2_LOW_RX_POWER_ALARM : Set|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 LC/0/2/CPU0:Dec 2 20:30:42.568 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_3_LOW_RX_POWER_ALARM : Set|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 LC/0/0/CPU0:Dec 2 20:30:54.301 UTC: pfm_node_lc[305]: %PLATFORM-NP-2-NP_DIAG : Clear|prm_server_to[163922]|0x1008000| NP diagnostics warning on NP0. LC/0/0/CPU0:Dec 2 20:31:07.323 UTC: pfm_node_lc[305]: %PLATFORM-NP-2-NP_DIAG : Set|prm_server_to[163922]|0x1008000| NP diagnostics warning on NP0. LC/0/0/CPU0:Dec 2 20:31:22.013 UTC: pfm_node_lc[305]: %PLATFORM-NP-2-NP_DIAG : Clear|prm_server_to[163922]|0x1008000| NP diagnostics warning on NP0. LC/0/0/CPU0:Dec 2 20:31:35.035 UTC: pfm_node_lc[305]: %PLATFORM-NP-2-NP_DIAG : Set|prm_server_to[163922]|0x1008000| NP diagnostics warning on NP0. LC/0/0/CPU0:Dec 2 20:31:49.615 UTC: pfm_node_lc[305]: %PLATFORM-NP-2-NP_DIAG : Clear|prm_server_to[163922]|0x1008000| NP diagnostics warning on NP0. LC/0/2/CPU0:Dec 2 20:31:51.939 UTC: vic_0_0[390]: %PLATFORM-VIC-4-BER_SF_ALARM : port: 0, SF-BER, status: set LC/0/2/CPU0:Dec 2 20:31:52.029 UTC: ifmgr[216]: %PKT_INFRA-LINK-3-UPDOWN : Interface HundredGigE0/2/0/0, changed state to Up LC/0/2/CPU0:Dec 2 20:31:52.029 UTC: ifmgr[216]: %PKT_INFRA-LINEPROTO-5-UPDOWN : Line protocol on Interface HundredGigE0/2/0/0, changed state to Up LC/0/2/CPU0:Dec 2 20:31:52.082 UTC: vic_0_0[390]: %PLATFORM-VIC-4-BER_SF_ALARM : port: 0, SF-BER, status: cleared LC/0/0/CPU0:Dec 2 20:32:02.637 UTC: pfm_node_lc[305]: %PLATFORM-NP-2-NP_DIAG : Set|prm_server_to[163922]|0x1008000| NP diagnostics warning on NP0. LC/0/0/CPU0:Dec 2 20:32:02.638 UTC: prm_server_to[318]: %PLATFORM-NP-0-LC_RELOAD : NP0 had 3 fast resets within an hour, initiating NPdatalog collection and automatic LC reboot RP/0/RSP1/CPU0:Dec 2 20:32:46.287 UTC: pfm_node_rp[385]: %PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED : Set|online_diag_rsp[225402]|System Punt/Fabric/data Path Test(0x2000004)|failure threshold is 3, (slot, NP) failed: (0/0/CPU0, 0) LC/0/2/CPU0:Dec 2 20:32:52.613 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_0_LOW_RX_POWER_ALARM : Clear|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 LC/0/2/CPU0:Dec 2 20:32:52.613 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_1_LOW_RX_POWER_ALARM : Clear|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 LC/0/2/CPU0:Dec 2 20:32:52.614 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_2_LOW_RX_POWER_ALARM : Clear|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 LC/0/2/CPU0:Dec 2 20:32:52.614 UTC: pfm_node_lc[305]: %PLATFORM-CPAK-2-LANE_3_LOW_RX_POWER_ALARM : Clear|envmon_lc[163927]|0x1005000|HundredGigE0/2/0/0 RP/0/RSP0/CPU0:Dec 2 20:33:23.195 UTC: pfm_node_rp[385]: %PLATFORM-DIAGS-3-PUNT_FABRIC_DATA_PATH_FAILED : Set|online_diag_rsp[233600]|System Punt/Fabric/data Path Test(0x2000004)|failure threshold is 3, (slot, NP) failed: (0/0/CPU0, 0) LC/0/0/CPU0:Dec 2 20:35:53.345 UTC: prm_server_to[318]: %PLATFORM-NP-0-LC_RELOAD : LC Recovery started LC/0/0/CPU0:Dec 2 20:35:53.345 UTC: pfm_node_lc[305]: %PLATFORM-NP-0-FAILED_LC_RELOAD : Set|prm_server_to[163922]|0x1008000|An unrecoverable error has been detected. The linecard will be reloaded. LC/0/0/CPU0:Dec 2 20:35:53.346 UTC: pfm_node_lc[305]: %PLATFORM-PFM-0-CARD_RESET_REQ : Card reset requested by: Process ID: 163922 (prm_server_to), Target node: 0/0/CPU0, CondID: 1048, Fault Reason: An unrecoverable error has been detected. The linecard will be reloaded.
destination interface of monitor-session/span goes down
Remove monitor-session from source interface before bringing down the span destination interface
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.