Traffic is getting dropped due to OCE_ADJ_DROP. When checking the specific prefix in the FIB, it is listed as inactive and within service-path as blackholed. cedge#sh sdwan ip fib vpn 399 | i 10.y.y.y /32 399 10.y.y.y /32 inactive - - - 10.x.x.x - cedge#show sdwan policy service-path vpn 399 interface gigabitEthernet 0/0/0.399 source-ip x.x.x.x dest-ip 10.y.y.y protocol 6 all Number of possible next hops: 1 Next Hop: Blackhole
1. cEdge is running version 17.3, 17.4, or 17.6. 2. Certain routes which should be Active are listed as Inactive in the FIB. 3. When running conditional debug against traffic going to that prefix will be seen as "Ipv4NoRoute" or "SdwanDataPolicyDrop" 4. When checking the hardware programming, the next hop OCE shows "nhobj_type ADJ_DROP" or "OCE_ADJ_DROP"
At this time, it may be possible that the issue can be temporarily resolved by performing a reboot. Otherwise, please open a TAC case for further assistance.