Upgrading a Nexus platform from a 9.3(4) or earlier image to a 10.3 image will fail with the following error message: N9K# install all nxos bootflash:nxos64-cs.10.3.2.F.bin Installer will perform compatibility check first. Please wait. Installer is forced disruptive "Failed to process nxos image". Pre-upgrade check failed. Return code 0x404F0003 (SRG file not present/some modules are not supported in target image). Setting the boot variable will fail as well. N9K(config)# boot nxos bootflash:nxos64-cs.10.3.2.F.bin Performing image verification and compatibility check, please wait.... Image provided does not exist. Failed to set the boot variable: image not found (0x40450008)
This is only applicable to Cloud Scale platforms supported on nxos64-cs.10.3.2.F.bin or any nxos images greater than 2G in size.
Intermediate upgrade to 9.3(10) and later images.
For upgrades failing from 9.3(5) - 9.3(9) to 10.3(1) and later, please check CSCwb63451.