Packet-trace feature on Lightspeed cards is broken when any slice on the card is down. Packet marking works, but counting of traced packets is broken. RP/0/RSP0/CPU0:ipe-zhb910-r-en-50#show controller np server trace error loc 0/1/CPU0 Tue Jul 13 23:01:39.378 CEST 14 wrapping entries (2112 possible, 64 allocated, 0 filtered, 14 total) Jul 13 12:30:21.617 npu_server/error 0/1/CPU0 t5538 npu_svr_pkt_trace_enable_np: cluster 0 NP4 ls_csr_read failed (rc=0xad81a200)! Jul 13 12:30:21.631 npu_server/error 0/1/CPU0 t5538 npu_svr_pkt_trace_enable(520): npu_svr_pkt_trace_enable_np fail ad81a200:'RDM Library' detected the 'fatal' condition 'ASIC is in a failed state'
Any slice on the card is powered off. Example: hw-module location 0/0/CPU0 slice 2 power-down hw-module location 0/0/CPU0 slice 3 power-down hw-module location 0/0/CPU0 slice 4 power-down hw-module location 0/0/CPU0 slice 5 power-down hw-module location 0/1/CPU0 slice 4 power-down hw-module location 0/1/CPU0 slice 5 power-down hw-module location 0/1/CPU0 slice 6 power-down RP/0/RP0/CPU0:PRM13#sh controllers np summary all location 0/0/cPU0 Tue Jul 13 21:00:12.703 UTC Node: 0/0/CPU0: ---------------------------------------------------------------- [total 9 NP] RDL Version 1350 H/W Rev: 1 Vendor ID: 0x01137 Device ID: 0x0a002 Ucode: /opt/cisco/XR/packages/asr9k-gcp-fwding-64-1.0.0.0-r75113I/lc/instances/BLACKBOLT-LC/ucode/viking-lightspeedp-fs-prod.mucode NP clock frequency: 650 MHz HBM frequency: 1600 MHz NP Reset Threshold/Action/Logging: 5/Slice Down/Enable: Tue Jul 13 20:11:18 NP State Loc PON Reset Hard Reset Details --- ----- --- --------- ---------- ----------------------------------------- NP0 UP MB 1 0 Init Successful NP1 DOWN MB 1 0 Not Present NP2 DOWN MB 1 0 Not Present NP3 DOWN MB 1 0 Not Present NP4 UP PEC 1 0 Init Successful NP5 UP PEC 1 0 Init Successful NP6 DOWN PEC 0 0 Not Present: Cache Enabled NP7 DOWN PEC 0 0 Not Present: Cache Enabled NP8 DOWN PEC 0 0 Not Present: Cache Enabled
Power on all slices
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.