ASR1k with ESP200-x might crash due to PA2_CSR32_TOP_CSR_PA_ERR_LEAF_INT__INT_PPE_INT1 when running L2TP/PPP sessions. The following logs would be generated in such crash: %CPPHA-3-FAULT: F0: cpp_ha: CPP:0.1 desc:PA2_CSR32_TOP_CSR_PA_ERR_LEAF_INT__INT_PPE_INT1 det:DRVR(interrupt) class:OTHER sev:FATAL id:1269 cppstate:RUNN ING res:UNKNOWN flags:0x7 cdmflags:0x8 %CPPOSLIB-3-ERROR_NOTIFY: F0: cpp_ha: cpp_ha encountered an error -Traceback= 1#1f705fb92752c97836ee39e07a38679d errmsg:7F6966BC4000+D20 cpp_common_os :7F696B9E7000+DCEC cpp_common_os:7F696B9E7000+19E8E cpp_drv_cmn:7F6969268000+42EAF :559BE9C5D000+2B043 :559BE9C5D000+2AC1D :559BE9C5D000+2A89A :559BE9C5D000+1A4E5 :559BE9C5D 000+194DC cpp_common_os:7F696B9E7000+11AF1 cpp_common_os:7F696B9E7000+121BE evlib:7F6964B5E000+8D8E evlib:7F6964B5E000+9A9C cpp_common_os:7F696B9E7000+13BD2 :559BE9C5D000+15 074 c:7F695A4C8000+240FD %CPPHA-3-FAULTCRASH: F0: cpp_ha: CPP 0.1 unresolved fault detected, initiating crash dump. %CPPHA-3-FAULTCRASH: F0: cpp_ha: CPP 0.1 unresolved fault detected, initiating crash dump. %CPPDRV-6-INTR: F0: cpp_driver: pyon(1) Interrupt : 21-May-13 07:53:51.380512 UTC+0300:PA2_CSR32_TOP_CSR_PA_ERR_LEAF_INT__INT_PPE_INT1 %IOSXE-3-PLATFORM: F0: cpp_cdm: CPP crashed, collecting state. %CPPDRV-3-LOCKDOWN: F0: fman_fp_image: QFP0.0 CPP Driver LOCKDOWN encountered due to previous fatal error (HW: QFP interrupt). %CPPDRV-3-LOCKDOWN: F0: cpp_cp: QFP0.0 CPP Driver LOCKDOWN encountered due to previous fatal error (HW: QFP interrupt). %IOSXE_OIR-6-OFFLINECARD: Card (fp) offline in slot F0 %IOSXE_RP_ALARM-6-INFO: ASSERT MAJOR module F0 Unknown state %IOSXE_RP_ALARM-2-ESP: ASSERT CRITICAL module R0 No Working ESP
N/A On ESP200-X, ESP200 appears not affected.
N/A
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.