Crash of the l2fib_show_client process on the RP when executing "show l2vpn forwarding bridge hardware ingress detail location 0/x/CPU0" CLI when storm control is configured within the bridge-domain.
6.5.3 SMU for CSCvt24805 is installed, or a smu that supercedes CSCvt24805.
No workaround of the CLI crash if the above smu is installed. However, the crash occurs on a process that is spawned specifically for displaying the hardware programming and state of the bridge-domain on the platform. It is not service impacting.
This defect is not in the baseline code base. It exists as collateral from SMU installation.