CU wants the interceptor ID to display correctly.
The BNG interceptor ID in ASR 9006 is shown inverted.
When LI Taps are applied via Radius config , in Little endian devices like ASR9006 , intercept ID was found to be inverted.
Endian conversion of intercept id is done so that it can be stored properly and it works for both Little/Big Endian machine.
Issue is due to Endianness conversion where customer is hitting the problem while using ASR9006 (little Endian) machine. Not seen in ASR9001(Big Endian) device. This is a Day0 issue and is caused because of the way LI is storing the intercept id in its Database. LI stores intercept id as an Integer which is causing problem in Little Endian devices as the byte order will be reversed.